Hubei EverBrite Opto Electronics Co. Ltd

Quality

Compliance, reliability testing and handling guidance for EverBrite LED packages.

RoHS compliant, LM-80 tested, EN 62471 / IEC TR 62778

Compliance

Ask us for the certificates and reports of the exact part you need. Typical documents:

  • RoHS compliance declaration
  • LM-80 lumen maintenance report for the LED light source
  • Photobiological safety assessment to EN 62471 / IEC TR 62778
  • Reliability test results to JEDEC JESD22 methods

Reliability tests

Reliability tests follow JEDEC JESD22 methods, with 22 pieces per test. Example: the test plan of the CER3535 A22 series.

TestStandardConditionsDuration
High-temperature storageJESD22-A103100 ± 5 °C1000 h
Low-temperature storageJESD22-A119−40 ± 5 °C1000 h
Thermal shockJESD22-A104100 °C, 30 min ↔ −40 °C, 30 min (15 s transfer)1000 cycles
ReflowJESD22-B106Peak 260 °C for 10 s3 cycles
Life testJESD22-A108Ta = 25 ± 5 °C, IF = 1500 mA1000 h
High-temperature life testJESD22-A108Ta = 105 ± 5 °C, IF = 1500 mA1000 h
High temperature and humidity life testJESD22-A10185 ± 5 °C / 85 % RH, IF = 1500 mA1000 h

Storage and handling

  • Store unopened bags at 5–30 °C and no more than 50 % RH. If stored for more than 3 months, bake at 65 °C for 24 hours before use.
  • After opening a bag, solder the parts within 12 hours. Keep the rest sealed, or at 5–40 °C and no more than 30 % RH.
  • If a bag has been open for 24 to 168 hours, or its humidity card has turned from blue to pink, bake at 65 °C for 24 hours. After 168 hours, take the parts off the tape and bake at 150 °C for 2 hours.
  • Reflow no more than twice, following the profile in the part’s datasheet.
  • Hold parts by their sides with tweezers. Do not press the silicone lens or stack assembled boards.
  • Use ESD protection: wrist straps or anti-static gloves, and grounded equipment.
  • Keep parts away from corrosive gases, which can discolour the silver-plated leadframe.
Reflow profile with 245 °C peak
Example reflow soldering profile (peak 245 °C)